Електронски системи за заклучување EKS


Филтри
Подреди производи според
Производител
  • 35
Цена до
На залиха
  • 0
Група
  • 14
  • 2
  • 6
  • 4
  • 2
  • 2
  • 1
  • 4


Електронски системи за заклучување EKS


Electronic-Key-System EKS with data interface offers maximum flexibility. As the user, you specify the data structure on the Electronic-Key and define how it is to be interpreted. For this purpose, you program the processing logic in the control system to suit your needs exactly.

EUCHNER Electronic-Key adapter with PROFIBUS DP interface FSA version ; 100378

EKS-A-IDXA-G01-ST09/03/04 Electronic-Key adapter with PROFIBUS DP interface read/write system Remote installation Electronic-Key adapter and electronics in one housing
-
Need to order

(Во моментов нема залиха)

Цена по барање

EUCHNER Interface adapter EKS Light modular (supports all operating states) EKS-A-APR-G08; 113647

Interface adapter EKS Light modular (supports all operating states) Interface adapter with 4-bit parallel interface Use in conjunction with Electronic-Key adapter
-
Need to order

(Во моментов нема залиха)

Цена по барање

EUCHNER Electronic-Key adapter with Ethernet TCP/IP interface FSA version ; 099265

EKS-A-IEXA-G01-ST02/03/04 Electronic-Key adapter with Ethernet TCP/IP interface Read/write system Remote installation Electronic-Key adapter and electronics in one
-
Need to order

(Во моментов нема залиха)

Цена по барање

EUCHNER Electronic-Key read/write red EKS-A-K1RDWT32-E; 077859

Electronic-Key read/write red EKS-A-K1RDWT32-E; 077859
-
Need to order

(Во моментов нема залиха)

Цена по барање

EUCHNER Electronic-Key read/write orange EKS-A-K1OGWT32-EU (Order no. 123098)

Electronic-Key read/write orange EKS-A-K1OGWT32-EU (Order no. 123098) Memory 116 bytes E²PROM (programmable) plus 8 bytes ROM (serial number)
-
Need to order

(Во моментов нема залиха)

Цена по барање

EUCHNER Interface adapter EKS PROFINET modular ; 122352

EKS-A-AIX-G18 Interface adapter with PROFINET IO interface read/write system Usage in conjunction with Electronic-Key adapter FHM A complete read/write station comprises
-
Need to order

(Во моментов нема залиха)

Цена по барање

EUCHNER Electronic-Key read/write blue EKS-A-K1BUWT32-EU; 091045

Electronic-Key read/write blue EKS-A-K1BUWT32-EU; 091045
-
Need to order

(Во моментов нема залиха)

Цена по барање

EUCHNER Interface adapter EKS Light FSA modular (supports all operating states) EKS-A-APRA-G08; 113645

Interface adapter EKS Light FSA modular (supports all operating states) Interface adapter with 4-bit parallel interface Use in conjunction with Electronic-Key adapter
-
Need to order

(Во моментов нема залиха)

Цена по барање

EUCHNER Electronic-Key adapter EKS Front hook modular FHM, with flying lead ; 106585

EKS-A-SFH-G30-2000 Small design for installations where there is little space Installation in standard assembly hole Ø 22.5 mm Closed design, rounded contours
-
Need to order

(Во моментов нема залиха)

Цена по барање

EUCHNER EKS Electronic-Key adapter FHM, with flying lead 3m, EKS-A-SFH-G30-3000 (Order no. 158353)

EKS Electronic-Key adapter FHM, with flying lead 3m, EKS-A-SFH-G30-3000 (Order no. 158353) Small design for installations where there is little space Installation
-
Need to order

(Во моментов нема залиха)

Цена по барање

EUCHNER ANWPG TRANSPONDER CODING; 067190

Transponder Coding (TC) Software for reading and writing CIS data carriers or EKS Electronic-Keys
-
Need to order

(Во моментов нема залиха)

Цена по барање

EUCHNER Electronic-Key adapter with PROFIBUS DP interface EKS-A-IDX-G01-ST09/03; 084800

Electronic-Key adapter with PROFIBUS DP interface Electronic-Key adapter with PROFIBUS DP interface in housing G01 Read/write system Remote mounting Electronic-Key
-
Need to order

(Во моментов нема залиха)

Цена по барање

EUCHNER Interface adapter EKS PROFINET modular version FSA ; 122353

EKS-A-AIXA-G18 Interface adapter with PROFINET IO interface read/write system Usage in conjunction with Electronic-Key adapter FHM A complete read/write station
-
Need to order

(Во моментов нема залиха)

Цена по барање

EUCHNER SW EKS DATA SERVICE (Order no. 8163316)

EKS Data Service (optional software expansion) Central software for providing access rights and access data from the PC into the PLC environment Simple online disabling
-
Need to order

(Во моментов нема залиха)

Цена по барање

EUCHNER Electronic Key Manager EKM demo version ANWPG ELECTRONIC KEY MANAGER DEMO; 093320

Electronic Key Manager EKM demo version Software for key management Only local EKM client, no network support Access to key database and key database export/import
-
Need to order

(Во моментов нема залиха)

Цена по барање


Страница 2 од 3
Прикажано 16 - 30 од 35 податоци

Електронски системи за заклучување EKS


Electronic-Key-System EKS

EKS with data interface offers maximum flexibility. As the user, you specify the data structure on the Electronic-Key and define how it is to be interpreted. For this purpose, you program the processing logic in the control system to suit your needs exactly. Numerous possible scenarios can be depicted in this way.← For example:
  • Control of certain machine functions
  • Storage of process parameters
  • Traceability of events
  • Storage of an expiry date on the Electronic-Key
  • Different access rights for multiple processes

Benefits for you

  • Safe, controlled access to your processes
  • Automatic logging on and logging off by placing the Electronic-Key
  • Variety of possible applications in all sectors due to industrial housing
  • Straightforward integration by means of various interfaces
  • Increased product quality due to controlled manufacture
  • Increased reliability of your installations and as a result lower production costs

Compact design

For the compact design, the Electronic-Key adapter and the electronics are mounted in one housing. The Electronic-Key is inserted into the Electronic-Key adapter and is held in place by a spring clip.←
  • Electronic-Key adapter and electronics in one housing
  • Very reliable retention of the Electronic-Key, even if there is heavy vibration
  • Robust housing for use in harsh environments

Version FSA

The FSA devices also have a second, redundant channel, which is generally available in the form of an additional semiconductor switching contact. This switching contact is used with functionally safe applications.

Modular design

With the modular design, the Electronic-Key adapter and electronics are mounted physically separated. Due to the separation, the Electronic-Key adapter fits in standard mounting bores with Ø 22.5 mm. The rounded shape of the Electronic-Key adapter and the FDA-approved plastic permit use in hygienically sensitive areas. With this design, the Electronic-Key is only held in front or dropped into place.←
  • Electronic-Key adapter mounted physically separated from the electronics
  • Straightforward installation in standard mounting bore Ø 22.5 mm
  • Suitable for hygienic areas
  • Very robust housing for use in extremely harsh environments

Electronic-Key-System EKS Light

EKS Light is optimized for quick, straightforward integration into a control system environment. For this purpose, the Electronic-Key has a pre-defined data structure that is evaluated directly by the read-only station.← With EKS Light, you therefore procure not just the EKS hardware, but an integrated solution for managing user groups (who is allowed to access what?) and access levels (what is the user allowed to do?).← For this purpose, the data structure on the Electronic-Key and the evaluation electronics in the read-only station form a closed system with user group identification and up to 16 access levels that can be used directly for a suitable application.← The complete evaluation logic for Electronic-Key detection is already integrated into the device and therefore does not need to be programmed into a control system.← The device first determines whether the Electronic-Key read is valid and access to the machine is authorized. If this is the case, the access level is determined and transferred to the control system via the 4-bit parallel interface. The authorization for a specific machine function must be assigned in the control system for each access level detected; the machine function is enabled in this way.


ЕЛЕКТРО ПНЕУМАТИК СОЛУШН ДОО СКОПЈЕ

  • ХРИСТО ТАТАРЧЕВ бр.47 К-лок. 4, СКОПЈЕ - КИСЕЛА ВОДА, КИСЕЛА ВОДА, Кисела Вода, Република Северна Македонија
  • Работно време: Ponedeljak - Petak 08 - 16h
  • Телефон:
  • +389 2 2774 523
  • +389 2 2774 523
  • email: sazdev@ep-solutions.mk

linkedin youtube instagram twitter facebook
1
2
3
Спореди производи Отстрани ги сите производи