Multifunctional Gate Box MGB
Филтри
Multifunctional Gate Box MGB
MGB-AP for use as a single device; MGB-AR for series connection up to 10 MGB-AR devices; MGB-PN for Profinet connection; MGB Ethernet/IP for Ethernet connection.
EUCHNER Interlocking module MGB-L0-APA-AA1A2-S1-L-112598 ; 112598
Interlocking module MGB-L0-APA..., without controls or indicators, RC18, on mounting plates Interlocking (without guard locking) With plug connector RC18 Mounted
-

(Во моментов нема залиха)
Цена по барање
EUCHNER Locking set MGB-L1HE-ARA-R-111940; 111940
Locking set MGB-L1HE-ARA... (guard locking by spring force) without controls or indicators, RC18 Guard locking with guard lock monitoring Can be connected in series
-

(Во моментов нема залиха)
Цена по барање
EUCHNER Locking set MGB-L1HE-ARA-L-111944; 111944
Locking set MGB-L1HE-ARA... (guard locking by spring force) without controls or indicators, RC18 Guard locking with guard lock monitoring Can be connected in series
-

(Во моментов нема залиха)
Цена по барање
EUCHNER Locking set MGB-L1HE-ARA-L-157851; 157851
Locking set MGB-L1HE-ARA... (guard locking by spring force) with 2 pushbuttons, key-operated rotary switch, RC18 Guard locking with guard lock monitoring Can be
-

(Во моментов нема залиха)
Цена по барање
EUCHNER Locking set MGB-L1H-ARA-R-121509; 121509
Locking set MGB-L1H-ARA..., (guard locking by spring force) with 2 pushbuttons, emergency stop, incl. label carrier Guard locking with guard lock monitoring Can
-

(Во моментов нема залиха)
Цена по барање
EUCHNER Locking set MGB-L2...-PN (guard locking by solenoid force) with 5 control elements, 7/8'' and M12 plugs, MGB-L2HEB-PNA-L-161484
Guard locking with guard lock monitoring Emergency stop according to ISO 13850, illuminated 4 illuminated pushbuttons including adhesive labels Connection via 7/8"
-

(Во моментов нема залиха)
Цена по барање
EUCHNER Locking set MGB-L1H-ARA-L-121211; 121211
Locking set MGB-L1H-ARA..., (guard locking by spring force) with 2 pushbuttons, emergency stop, incl. label carrier, RC26 Guard locking with guard lock monitoring
-

(Во моментов нема залиха)
Цена по барање
EUCHNER Locking set MGB-L1H-ARA-L-111656; 111656
Locking set MGB-L1H-ARA... (guard locking by spring force) with 2 pushbuttons, incl. label carrier, RC18 Guard locking with guard lock monitoring Can be connected
-

(Во моментов нема залиха)
Цена по барање
EUCHNER Locking module MGB-L1C-ARA-L-109799; 109799
Locking module MGB-L1-ARA... (guard locking by spring force) with 3 pushbuttons, 2 indicators, emergency stop, incl. label carrier, RC26 Guard locking with guard
-

(Во моментов нема залиха)
Цена по барање
EUCHNER Locking module MGB-L1-ARA-AA1A1-S1-L-111074; 111074
Locking module MGB-L1-ARA... (guard locking by spring force) without controls or indicators, RC18 Guard locking with guard lock monitoring Can be connected in series
-

(Во моментов нема залиха)
Цена по барање
EUCHNER Locking module MGB-L1-ARA-AP7A1-M-L-121406; 121406
Locking module MGB-L1-ARA..., (guard locking by spring force) with 2 pushbutton, emergency stop, selector switch Guard locking with guard lock monitoring Can be
-

(Во моментов нема залиха)
Цена по барање
EUCHNER Interlocking set MGB-L0H-ARA-R-124258; 124258
Interlocking set MGB-L0H-ARA..., with 2 pushbuttons, incl. label carrier, RC18 Interlocking (without guard locking) Can be connected in series with other AR devices
-

(Во моментов нема залиха)
Цена по барање
EUCHNER Locking set MGB-L2HE-ARA-R-121191; 121191
Locking set MGB-L2HE-ARA... (guard locking by solenoid force) with 2 pushbuttons, emergency stop, incl. label carrier, RC18 Guard locking with guard lock monitoring
-

(Во моментов нема залиха)
Цена по барање
EUCHNER Locking set MGB-L2HE-ARA-L-121072; 121072
Locking set MGB-L2HE-ARA... (guard locking by solenoid force) with 2 pushbuttons Guard locking with guard lock monitoring Can be connected in series with other AR
-

(Во моментов нема залиха)
Цена по барање
EUCHNER Locking module MGB-L1-ARA-AL2A1-M-R-121060; 121060
Locking module MGB-L1-ARA..., (guard locking by spring force) with 2 pushbutton Guard locking with guard lock monitoring Can be connected in series with other AR
-

(Во моментов нема залиха)
Цена по барање
Multifunctional Gate Box MGB
The MGB is a safety system with guard locking and guard lock monitoring for the protection of safety doors on machines and installations.
Economical, standard-compliant wiring
The family MGB-AP is particularly suitable for the protection of individual safety doors. If series connection is not necessary, wiring can then be saved. This version has different timing to the AR version.All devices in the family MGB-AR can be wired directly in series in a so-called AR series connection without reducing safety or the PL. As a consequence evaluation units are saved.
AR devices are also available in the EUCHNER series CES and CET.
Seamless integration by means of bus connection
In the PROFINET version, MGB-PN, we now also make the wiring easier for you. You define which element is to be integrated and the related function. The MGB supplies the protocol frame with the necessary PROFINET input and output bytes required. Comprehensive diagnostic information in the form of PROFINET messages makes troubleshooting quick and specific. Due to the typical ease with which parameters can be set in PROFINET, even the replacement of the system in case of servicing is a simple matter and can be undertaken in a few minutes.In the MGB Ethernet/IP™ version, we now also make the wiring easier for you. You define which element is to be integrated and the related function. The MGB supplies the protocol frame with the necessary CIP Safety input and output bytes required. Whether interlocking, guard locking, escape release or other functions such as buttons for start/stop, emergency stop, selector switch, etc. – the MGB meets all requirements for safety-related applications and can be equipped on a customer-specific basis. Comprehensive diagnostic information in the form of Ethernet/IP™ messages provides a fast and detailed overview of the device status. Due to the ease with which parameters can be set, even replacing the system during servicing is a simple matter and takes no more than a few minutes.